Prod.No. 93513 EAN: 4007529935130 PD2N-KNXs-DX-FM
- Voltage: via KNX BUS
- Dimensions: FM= Ø 106 x 42 mm
- Typ. power input: 12 mA
- Features
- Description
- Accessories
- Downloads
Features
Designation | Value |
---|---|
Voltage | via KNX BUS |
Dimensions | FM= Ø 106 x 42 mm |
Typ. power input | 12 mA |
Detection area | horizontal 360° (Ceiling mounting) |
Range |
max. Ø 10 m across max. Ø 6 m towards max. Ø 4 m seated |
Monitored area (tangential movement) | 78 m² / 2.5 m mounting height |
Mounting height min./max./recommended | 2 m / 5 m / 2.5 m |
Degree / class of protection | FM= IP20 / Class III |
Impact strength | IK05 |
Temperature measurement range | -5 °C to +45 °C |
Ambient temperature | -25 °C to +55 °C |
Housing | polycarbonate, UV-resistant |
Number of light sensors | 2 |
Material color | white mat, similar to RAL9010 |
Number of PIR sensors | 1 |
KNX TP 256 | Yes |
Orientation light | 5 – 100 % / OFF / 1 min – 255 min |
Night light | 5 – 100 % |
Brightness set value | 5 – 2000 Lux |
Description
KNX occupancy detector with integrated KNX bus connector
KNX Secure ready
HCL/RGB control
Parameterisation from ETS 5 for integration into KNX systems
Individual adaption of the PIR sensor sensitivity
Mixed light measurement using internal, external and remote (optional) light sensors
Intelligent semi-automatic mode, occupancy-independent regulating mode (photoelectric switch), full automatic mode
1 x Light (for regulating or switching), 1 x slave output, 3 separate HVAC-blocs
Regulation of up to three lighting groups using offset (external influence possible)
Short presence, self-adjusting follow-up time, corridor function
Various locking functions
Soft-start
Two logic modules
Recall of light scenes
Deactivatable status indicators
Temperature- and noise sensor
The product database for import into the ETS database can be downloaded from the B.E.G. homepage.
Detection area can be extended thanks to master-slave-mode
Extensive optimization options for light measurement
Measured light value is communicated to the bus
Adaption of dimming curve
Bidirectionally remote control-capable with the IR adapter and the B.E.G. smartphone app
PIN code
IR remote control-capable via IR remote control (optionally)
5 button remote control, programmable at choice (accessory)
Programming button (phys. address) can be operated via remote control
HVAC mode (0=automatic, 1=comfort, 2=stand-by, 3=economy, 4=antifreeze/heat protection)
Manual influence via external KNX push buttons possible
Function control (heartbeat, cyclical sending)
Occupancy simulation
Forced switch-off
Intelligent central-off function
Premonition of switch-off
Burn-in function for fluorescent lamps selectable from 1h till 100h
Behaviour upon bus voltage return definable at choice
Variable safety pause after switching off the lights
Typical applications:
Offices, conference rooms, schools, nursery schools, hospitals